Mitsubishi 3-Phase Uninterruptible Power Supplies

We Design and Build Data Centers
Designing, Engineering, Constructing, Commissioning, Maintening Mission-Critical Data Centers
If your operation cannot go down, you can rely on the Mitsubishi UPS's to deliver dependability when you need it most.
Page Overview: Shortcut links

Do not hesitate to call our engineers to discuss your application, you will find them knowledgeable and very helpful - this is what our customers say about us! (#480-563 4172)

 

1.-Mitsubishi 2033C UPS's: 3-phase True On Line Double Conversion units (10,15, 20kVA)


Mitsubishi UPS Systems: 10 to 20kVA UPS

Mitsubishi Uninterruptible Power Supplies: 2033C (10 to 20kVA)

  • high efficiency IGBT (converter/inverter), extended battery life
  • input power factor of 1.0
  • low input current harmonics: 4% THD (100% load), 7% THD (50% load)
  • UL924 approved
  • zero energy MBS
  • batteries included for reduced foot print
  • monitoring, management and shutdown software: NETCOM2 SNMP/web adapter
 

2.-Mitsubishi 2033G UPS's: 3-phase True On Line Double Conversion units (30kVA,50kVA)


Mitsubishi UPS Systems: 30kVA & 50kVA UPS

Mitsubishi Uninterruptible Power Supplies: 2033G (30kVA & 50kVA)

  • CSTBT [Carrier Stored Trench Gate Bipolar Transistor] IGBT(Converter/Inverter)
  • 1:1 Generator Compatibility
  • low Input Harmonics
  • advanced touch screen monitoring
  • external battery cabinets for extended battery time
  • 2-year warranty
  • UL924 listed
  • monitoring, management and shutdown software: NETCOM2 SNMP/web adapter
 

[Back to Top]

3.-Mitsubishi 2033A UPS's: 3-phase True On Line Double Conversion units (30 to 75kVA)

 
Mitsubishi UPS Systems: 30 to 75kVA UPS

Mitsubishi Uninterruptible Power Supplies: 2033A (30 to 75kVA)

  • high efficiency Intelligent Power Module transistors (converter/inverter)
  • extended battery life: step loads (0-100%) without the use of batteries
  • input power factor of 1.0
  • low input current harmonics: 3% THD (100% load),6% THD (50% load)
  • zero energy MBS
  • operator-friendly control panel
  • monitoring, management and shutdown software with paging and e-mail capability: NETCOM2 SNMP/web adapter
 

[Back to Top]

4.-Mitsubishi 2033D UPS's: 3-phase True On Line Double Conversion units (30 to 80kVA)

 
Mitsubishi UPS Systems: 30 to 80kVA UPS

Mitsubishi Uninterruptible Power Supplies: 2033D (30 to 80kVA): 480in/208 out or 480 out

  • IGBT technology (converter/inverter)
  • extended battery life: step loads (0-100%) without the use of batteries
  • input power factor of 1.0
  • low input current harmonics: 4% THD (100% load),7% THD (50% load)
  • zero energy MBS
  • operator-friendly control panel
  • monitoring, management and shutdown software with paging and e-mail capability: NETCOM2 SNMP/web adapter
 

[Back to Top]

5.-Mitsubishi 9700 UPS's: 3-phase True On Line Double Conversion units (100 to 225kVA)

 
Mitsubishi UPS Systems: 100 to 225kVA UPS

Mitsubishi Uninterruptible Power Supplies: 9700 (100 to 225kVA)

  • high efficiency IGBT (converter/inverter), extended battery life
  • input power factor of 0.99, 208in/208out
  • low input current harmonics: 3% THD (100% load), 5% THD (50% load)
  • designed for isolated redundant applications
  • monitoring, management and shutdown software with paging and e-mail capability: NETCOM2 SNMP/web adapter
 

[Back to Top]

6.-Mitsubishi 9800 UPS's: 3-phase True On Line Double Conversion units (100 to 750kVA)

 
Mitsubishi UPS Systems: 100 to 750kVA UPS

Mitsubishi Uninterruptible Power Supplies: 9800 (100 to 750kVA)

  • high efficiency IGBT for the inverter
  • input power factor of 0.90
  • low input current harmonics: 6% THD (100% load), 9% THD (50% load)
  • designed for isolated redundant applications and Diamond Sync configurations
  • Multi-Module Systems (MMS) with independent parallel control and bypass circuits
  • monitoring, management and shutdown software with paging and e-mail capability: NETCOM2 SNMP/web adapter
 

[Back to Top]

7.-Mitsubishi 9900 UPS's: 3-phase True On Line Double Conversion units (80 to 225kVA)

 
Mitsubishi UPS Systems: 80 to 225kVA UPS

Mitsubishi Uninterruptible Power Supplies: 9900 (80, 100, 150, 225, 300, 500, 750kVA)

  • 480in/480out, 3-wire + ground, no output transformer
  • fully Digital, IGBT Converter and Inverter
  • low input THD with NO leading power factor
  • parallel up to 4 modules (80kVA to 225KVA), up to 4000kVA (750kVA modules)
  • small footprint and light weight
  • 3 Year Warranty
  • advanced circuit topology and PWM
  • up to 97% efficiency
  • monitoring, management and shutdown software with paging and e-mail capability: NETCOM2 SNMP/web adapter
UPS + Vycon DC Flywheel

Vycon Direct Connect VDC and VDC-XE

When connected to the DC bus of the Mitsubishi UPS, the flywheel(s) allows to provide ride-through power to critical loads during electrical disturbances like sags, brownouts, momentary interruptions and power outages until the genset kicks in and takes over
  • single flywheel can provide up to 300kW of power
  • higher reliability than traditional battery backup
  • almost maintenance free (bearings do not need to be replaced)
  • unlimited cycling
  • recharges quickly
  • small foot print (30" (W) x 30" (D))
  • long life span: 20 years
  • connects to the UPS DC bus
  • parallel operation can provide ample time for genset to start for any kVA loads
 

[Back to Top]

8.-Mitsubishi Communication Software

 
Netcom SNMP/Web adapter

Mitsubishi Netcom2 Web/SNMP adapter

  • NetCom2 is a SNMP/Web agent hardware adapter runs an embedded Simple Network Management Protocol (SNMP)software agent. This agent responds to SNMP GETs and SETs and, also, forwards TRAPs to designated recipients when critical conditions occur to the Uninterruptible Power Supplies, such as going on battery backup.
    Design Features:
    • SNMP Traps
    • Local and Remote Shutdown
    • Data and Event logging and graphing
    • Network Broadcasting
    • Real-time Monitoring
    • Multi-user Support
    • Email and Alphanumeric paging

Additional Services
  • Preventive Maintenance programs and contracts
  • Extended Warranty
 

[Back to Top]

9.-Battery Replacement: Mitsubishi UPS's

 
Battery Replacement New batteries for Mitsubishi UPS's: Typically batteries need to be replaced after 3 to 5 years of operation

 

[Back to Top]

 

Request for Quotation - Mitsubishi UPS
Your name: Your company name:
Your e-mail: Your Phone Number:

I request a quote for:

Battery backup time required at full load:

Input and output voltages:

Additional Comments:

[Back to Top]